Certificate of Analysis
KLOW 80 mg

Timeline
Sample
Testing
Chromatograms
GHK-Cu / KPV
HPLC-UV
BPC-157 / TB-500
HPLC-UV
Analyst Comments
Blue lyophilized powder, black-cap vial, received sealed. Only GHK-Cu was found. BPC-157, TB-500 (full-length and fragment) and KPV were not detected (detection limit about 0.1 mg per vial). The dashed trace is a KLOW reference run on the same method, marking where KPV elutes. BPC-157 and TB-500 were checked on a second HPLC-UV method; that chromatogram is shown beside it.
Analyst Signature
Verification Code
Scan to Verify
Results apply solely to the sample as received and are not representative of any larger lot, batch, or production run. Findings are limited to the analytes stated above. PuriLab Analytical is an independent testing laboratory, is not CLIA certified or ISO 17025 accredited, does not sell or distribute any substance, and makes no representation as to the safety, legality, or fitness of any material for any use.