COA/KL-2026-003Verified
Save as PDFCertificate of Analysis
PuriLab Analytical
KLOW 80 mg
KL-2026-003Lot QL80PAnalyzed October 27, 2026

Timeline
Ordered
October 20, 2026
Received
October 23, 2026
Analyzed
October 27, 2026
Sample
Name
KLOW 80 mg
Expected
KLOW blend (GHK-Cu, BPC-157, TB-500, KPV)
Amount
1 vial, lyophilized powder
Testing
Client
Flatirons Research Co
Test type
Content & purity
Method
HPLC-UV
Content, how much is in it
GHK-Cu62.3mg
Label claim: 50 mg
BPC-15713.84mg
Label claim: 10 mg
TB-50010.82mg
Label claim: 10 mg
KPV11.88mg
Label claim: 10 mg
Purity, how clean it is
99.5%
Peptide purity, HPLC-UV peak area
Chromatogram
HPLC-UV
11.46 min, BPC-157, 61.5%
12.44 min, TB-500, 38.0%
Analyst Comments
Blue lyophilized powder, clear-cap vial, received sealed. GHK-Cu and KPV were measured on a second HPLC-UV method; the chromatogram shows the BPC-157 / TB-500 method.
Analyst Signature
Max Barrett
Lab Director, PuriLab Analytical
Analysis date: October 27, 2026
Verification Code
KL-GGB6-6UBT
Verify at purilab.org/verify/KL-GGB6-6UBT
Scan to Verify
KL-GGB6-6UBT
Results apply solely to the sample as received and are not representative of any larger lot, batch, or production run. Findings are limited to the analytes stated above. PuriLab Analytical is an independent testing laboratory, is not CLIA certified or ISO 17025 accredited, does not sell or distribute any substance, and makes no representation as to the safety, legality, or fitness of any material for any use.