COA/GH-2026-024Verified
Save as PDFCertificate of Analysis
PuriLab Analytical
GHK-Cu 50 mg
GH-2026-024Lot NOT PROVIDEDAnalyzed November 15, 2026

Timeline
Ordered
November 7, 2026
Received
November 13, 2026
Analyzed
November 15, 2026
Sample
Name
GHK-Cu 50 mg
Expected
GHK-Cu
Amount
1 vial, lyophilized powder
Testing
Client
Luis Salazar
Test type
Content & purity
Method
HPLC-UV
Content, how much is in it
39.75mg
Label claim: 50 mg
Purity, how clean it is
98.7%
by HPLC-UV peak area
Chromatogram
HPLC-UV
2.58 min, GHK-Cu, 98.7%
Analyst Comments
Blue lyophilized powder, blue-cap vial hand-marked Cu50, received sealed.
Analyst Signature
Max Barrett
Lab Director, PuriLab Analytical
Analysis date: November 15, 2026
Verification Code
GH-GS3W-ULUL
Verify at purilab.org/verify/GH-GS3W-ULUL
Scan to Verify
GH-GS3W-ULUL
Results apply solely to the sample as received and are not representative of any larger lot, batch, or production run. Findings are limited to the analytes stated above. PuriLab Analytical is an independent testing laboratory, is not CLIA certified or ISO 17025 accredited, does not sell or distribute any substance, and makes no representation as to the safety, legality, or fitness of any material for any use.