🧬 Coming soon: Rapid Microbial Screen.Sterility screening results in hours, not 14 days.Get notified →
PuriLab Analytical
COA/BT-2026-023Verified
Save as PDF

Certificate of Analysis

PuriLab Analytical

Wolverine 20 mg

BT-2026-023Lot NOT PROVIDEDAnalyzed November 11, 2026
Wolverine 20 mg vial as received

Timeline

Ordered
October 29, 2026
Received
November 4, 2026
Analyzed
November 11, 2026

Sample

Name
Wolverine 20 mg
Expected
Wolverine blend (BPC-157, TB-500)
Amount
2 vials (same product, conformity), lyophilized powder

Testing

Client
New Wave Aminos
Test type
Content & purity, fentanyl, conformity
Method
HPLC-UV
Content, how much is in it
BPC-157, bottle 119.63mg
Label claim: 10 mg
TB-500 (full-length TB4), bottle 19.80mg
Label claim: 10 mg
BPC-157, bottle 224.39mg
Label claim: 10 mg
TB-500, bottle 2Notdetected
Label claim: 10 mg
Purity, how clean it is
99.7% (bottle 1)
Bottle 1, HPLC-UV peak area. Measured, not estimated. Purity is calculated from the full chromatogram shown above.
Fentanyl
NOT DETECTED
Screening cutoff 20 ng/mL
Conformity
DOES NOT CONFORM
The bottles do not match. Bottle 1 contains BPC-157 and full-length TB-500 (TB4); bottle 2 contains BPC-157 only, with no TB-500 detected (full-length or fragment, detection limit about 0.05 mg). No average is given because the bottles differ. Solid trace is bottle 1, dashed trace is bottle 2. Bottle 1 received November 4, 2026, analyzed November 6, 2026. Bottle 2 received November 10, 2026, analyzed November 11, 2026.
VialContentPurity
Bottle 1BPC-157 19.63 mg / TB-500 9.80 mg99.7%
Bottle 2BPC-157 24.39 mg / TB-500 not detected99.4%

Chromatogram

HPLC-UV

mAU-100010020030040004812162024Retention time (min)11.2512.37
11.25 min, BPC-157, 71.6%
12.37 min, TB-500 (full-length TB4), 28.1%
Bottle 2 (TB-500 not detected)

Analyst Comments

White lyophilized powder, black-cap vials, received sealed.

Analyst Signature

Max Barrett
Lab Director, PuriLab Analytical
Analysis date: November 11, 2026

Verification Code

BT-VSH1-WYYO
Verify at purilab.org/verify/BT-VSH1-WYYO

Scan to Verify

BT-VSH1-WYYO

Results apply solely to the sample as received and are not representative of any larger lot, batch, or production run. Findings are limited to the analytes stated above. PuriLab Analytical is an independent testing laboratory, is not CLIA certified or ISO 17025 accredited, does not sell or distribute any substance, and makes no representation as to the safety, legality, or fitness of any material for any use.

PuriLab Analyticaladmin@purilab.org
Page 1 of 1