COA/BAC-2026-028Verified
Save as PDFCertificate of Analysis
PuriLab Analytical
Bacteriostatic Water 10 mL
BAC-2026-028Lot BA10-26060201 V10Analyzed November 11, 2026

Timeline
Ordered
November 6, 2026
Received
November 10, 2026
Analyzed
November 11, 2026
Sample
Name
Bacteriostatic Water 10 mL
Expected
Benzyl Alcohol (preservative)
Amount
1 vial, aqueous solution, multi-dose 10 mL, sealed
Testing
Client
IN Research
Test type
Preservative identity & content determination, pH
Method
HPLC-UV
Content, how much is in it
0.92%w/v
Label claim: 0.9% w/v
Identity, what it isMatch
Confirmed
Retention-time and UV spectrum match vs. benzyl alcohol reference standard
pH
6.73
USP range 4.5 to 7.0
Chromatogram
HPLC-UV
3.35 min, Benzyl Alcohol
Analyst Comments
Clear, colorless aqueous solution, grey flip-cap multi-dose vial, received sealed.
Analyst Signature
Max Barrett
Lab Director, PuriLab Analytical
Analysis date: November 11, 2026
Verification Code
BAC-WGZ4-4P93
Verify at purilab.org/verify/BAC-WGZ4-4P93
Scan to Verify
BAC-WGZ4-4P93
Results apply solely to the sample as received and are not representative of any larger lot, batch, or production run. Findings are limited to the analytes stated above. PuriLab Analytical is an independent testing laboratory, is not CLIA certified or ISO 17025 accredited, does not sell or distribute any substance, and makes no representation as to the safety, legality, or fitness of any material for any use.
PuriLab Analytical|admin@purilab.org
Page 1 of 1