COA/BAC-2026-005Verified
Save as PDFCertificate of Analysis
PuriLab Analytical
Reconstitution Solution (Bacteriostatic Water) 10 mL
BAC-2026-005Lot 260601Analyzed October 7, 2026

Timeline
Ordered
October 3, 2026
Received
October 6, 2026
Analyzed
October 7, 2026
Sample
Name
Reconstitution Solution (Bacteriostatic Water) 10 mL
Expected
Benzyl Alcohol (preservative)
Amount
1 vial, aqueous solution, multi-dose 10 mL, sealed
Testing
Client
Primordial Research
Test type
Preservative identity & content determination
Method
HPLC-UV
Content, how much is in it
1.09%w/v
Label claim: 0.9% w/v
Identity, what it isMatch
Confirmed
Retention-time match vs. same-day reference standard
Chromatogram
HPLC-UV
3.33 min, Benzyl Alcohol
Analyst Comments
Clear, colorless aqueous solution, blue cap multi-dose vial, received sealed.
Analyst Signature
Max Barrett
Lab Director, PuriLab Analytical
Analysis date: October 7, 2026
Verification Code
BAC-LS5F-YZPP
Verify at purilab.org/verify/BAC-LS5F-YZPP
Scan to Verify
BAC-LS5F-YZPP
Results apply solely to the sample as received and are not representative of any larger lot, batch, or production run. Findings are limited to the analytes stated above. PuriLab Analytical is an independent testing laboratory, is not CLIA certified or ISO 17025 accredited, does not sell or distribute any substance, and makes no representation as to the safety, legality, or fitness of any material for any use.